Pump Troubleshooting
11. 03, 2023
Water Pumps Troubleshooting Guide | ||
Problem | Causes | Troubleshootings |
The pump does not run | The pump is not powered on. | Check the power supply. |
Short circuit. If it keeps happending, the cable or motor is faulty. | Check the short circuit protection and test the power cables and motor. If there are issues with the power cables or motor, please contact customer support. | |
The motor has thermal protection. When the motor stator temperature exceeds 130 degrees, the thermal overload switch is activated. | Eliminate the overload fault, cut off the power supply and wait 3-5 minutes until the thermal overload switch is reset. | |
The motor is buzzing but doesn't run. | Check if the impeller is tangled, causing pump jamming. Check and replace the capacitor. | |
The pump runs but no water comes out | Low Supply Voltage to the Motor | Check the input circuit and voltage to ensure that the motor is receiving an adequate power supply. Verify that the voltage meets the requirements specified by the pump's manufacturer. |
Blocked Pipes or Pump Components | Clean and clear the pipes and pump to ensure smooth water flow. | |
Air in the Pump | Prior to starting the pump, it needs to be primed by filling the pump body with water to eliminate any air inside. Make sure the pump is primed properly before operation. | |
Inadequate Inlet Size | If the pump inlet size is too small, it may restrict the water intake capacity. Consider replacing the inlet pipe with a larger diameter to improve water intake. | |
Insufficient Suction Lift | If the water source is located far away from the pump, the suction lift may not be sufficient to draw water effectively. Try reducing the suction lift by bringing the water source closer to the pump or using alternative methods to reduce the vertical distance. | |
The pump vibrates | Foreign Objects in the Pump | Remove the foreign objects to restore smooth operation. |
Difficult Pump Rotation | Inspect the pump and manually rotate it to identify any issues or obstructions that may be hindering its rotation. Troubleshoot and address the problem accordingly. | |
Loose Power Connection | Check the connection points and reestablish a proper connection if necessary. | |
Inadequate Pump Fixation | Make sure the pump is properly anchored or fixed to prevent excessive movement. | |
The pump lift is not sufficient | Blockage | Check for any blockages within the pump that may be impeding its lifting capacity. Clear the blockage to restore proper functionality. |
Incorrect Pump Selection | Replace with a more suitable pump that can meet the desired specifications. | |
Closed Valves | Ensure that all relevant valves are open to allow for proper water flow and lifting capacity. | |
The motor is overheating | Insufficient Voltage | Address any voltage issues that may be causing overheating. |
Blockage | Clear the blockage to restore proper motor function. | |
Pump Jamming | Troubleshoot and resolve any pump jamming issues that may be leading to motor overheating. If necessary, seek assistance from customer support or a professional technician. | |
Blockage in Discharge Pipe | Clear any blockages in the discharge pipe that may be restricting water flow and causing the motor to overheat. | |
High Ambient Temperature or Poor Ventilation | Ensure that the pump is located in an environment with adequate cooling and ventilation to prevent excessive heat buildup. | |
Seized Bearings | Replace the bearings to address the issue. | |
Motor Malfunction | Contact after-sales if the motor itself is faulty. |